Experience that keeps you flowing.
Bursa, Türkiyeinfo@parlaproses.com

Pump engineering

Pump selection: how to determine flow and head

A practical selection guide that combines demand, elevation, terminal pressure and pipe losses at one operating point.

Illustrative engineering scenario · Assumptions are stated in the text.

Flow, elevation, terminal pressure and pipe losses in an illustrative water transfer system.
An explanatory diagram, not an installation drawing or a manufacturer performance curve.

AT A GLANCE

  • Define flow and head together as one duty point.
  • Calculate static lift, pressure demand and flow-dependent losses separately.
  • Validate final selection against the full curve, suction conditions and actual demand profile.

1. Define what the system must deliver

Pump selection starts with the duty, rather than motor power or connection size. Define the liquid, source, destination, required quantity and delivery period. Tank filling, continuous process supply and variable building demand require different approaches to flow. Dividing daily volume by every hour of the day can understate capacity when a tank must fill within a short window.

Record liquid temperature, density, viscosity and solids content. Do not directly apply a curve for clean, cold water to a viscous or hot liquid. State whether the pump transfers between open tanks or supplies a pressurised line; this establishes the boundaries of the head calculation.

2. Derive design flow from the delivery period

For tank filling, an initial relationship is Q = V / t. Filling a usable volume of 24 m³ in two hours requires an average pump flow of 12 m³/h. Any consumption during filling must be added. For building demand, assess an appropriate simultaneous-use assumption and the project demand profile rather than simply adding every fixture rating.

Record minimum, normal and maximum flow instead of a single number. A duty point occupied for many hours is particularly important for efficiency. Present future growth as a separate scenario; stacking uncertainty allowances can oversize the pump and make low-demand control more difficult.

3. Worked total-head calculation

The following example illustrates the method only; it is neither a Parla installation nor the performance of a particular product. Assume water is delivered at 12 m³/h from an open tank to a user 15 m higher. The user requires 2 bar gauge pressure, and calculated pipe losses at this flow are 5.6 m. Using approximately 1 bar = 10.2 m for water gives a pressure requirement of 20.4 m.

H = 15 + 20.4 + 5.6 = 41 m. This simplified calculation assumes an atmospheric source surface and neglects the velocity-head difference. Add the relevant terms for a pressurised source, a significant velocity difference or changing tank levels.

Annotated illustrative head budget at 12 m³/h
ComponentValueMeaning in the calculation
Elevation difference15 mHeight between source and delivery point.
Terminal pressure20.4 mApproximately equivalent to 2 bar for water.
Pipe and fitting losses5.6 mApplies only at the stated 12 m³/h flow.
Required total head41 mChecked together with flow on the selection curve.

4. Find one operating point on the curve

The calculated 12 m³/h and 41 m must be available together. Maximum flow and maximum head shown for a product family usually describe different ends of its envelope; they are not a simultaneous duty point. Actual operation occurs where the pump curve for the selected speed and impeller intersects the system curve.

Check candidates over the entire expected operating range as well as the design point. Assess the efficient region, permitted continuous flow range, power requirement and shut-off pressure. Do not size the motor solely from power at the design point; other points permitted by the system may impose additional load.

5. Include suction conditions in selection

A pump that supplies the required flow and head may still operate unreliably with unsuitable suction piping. Minimum source level, water temperature, suction losses and site elevation affect available NPSH. Compare it with the manufacturer’s required NPSH and the selected margin approach throughout the operating range.

Air pockets, leaks and blocked strainers can change the calculated conditions. Support piping without loading pump connections and retain maintenance access. In a closed circulation loop, do not automatically add the building’s entire height to pump head; circulation duty is assessed separately from filling and pressurisation.

6. Keep selection and acceptance criteria together

Before requesting a quotation, combine the flow range, head calculation, liquid data, electrical supply and installation conditions in one selection sheet. Include pipe sizes and valve positions. Suppliers can then assess the same boundary conditions, avoiding comparisons based only on motor rating.

After selection, prepare acceptance records for expected flow, suction and discharge pressure, electrical power and control settings. If commissioning measurements differ from design calculations, first check measurement positions, valve status and air. Choosing a product family is a starting point; the final model, hydraulic variant and motor require approval against the full curve.

Frequently asked questions

Is head only the vertical distance?+

No. In an open transfer system, elevation difference is combined with required pressure and losses, with available inlet pressure included using the correct sign. Use consistent reference points.

Is the maximum rated flow sufficient for selection?+

No. The required flow must be delivered at the required head. Check the curve for the chosen model, speed, impeller and frequency rather than family limits.

Which flow should I provide when demand varies?+

Provide minimum, normal and maximum flow, ideally with annual hours at each. This profile supports pump quantity, control and energy assessment.

Can I simply match the old motor rating?+

No. Establish measured flow, pressures, liquid properties and any operating problem. Pumps with the same motor rating can have different hydraulic characteristics.

Apply this assessment to your project.

Share your operating conditions, existing equipment and objective. Let’s assess product selection together with the technical documents.

Keep reading

Chat on WhatsApp