Electrically Actuated Threaded Ball Valve

Electric actuation for threaded branches

Fits an electrically switched branch where threaded connections are required. Check cable entry and maintenance clearance above the actuator separately from the pipework dimensions.

Threaded line connectionPTFE sealing elementActuator and valve body are selected together
Pipe connectionThreaded
BodyAISI 304 or AISI 316
Technical documents

Final selection requires the complete product code and the service conditions.

UNDERSTAND THE APPLICATION

A solution for your application.

Application areas

On/off isolation in process lines · Isolation of threaded utility branches

Selection considerations

Specify DN, end connection, medium, body and seat material.

Specify the nominal line size and connection standard, together with the need for isolation, regulation or automation. Two valves of the same nominal size may differ in materials or connection dimensions.

MANUFACTURER DATA

Technical specifications

Pipe connectionThreaded
BodyAISI 304 or AISI 316
SealingPTFE
Published maximum pressure63 bar
Published maximum temperature180 °C

Evaluate pressure and temperature together. Verify the ratings that apply to the selected body, sealing materials and end connections in the model-specific technical document.

DOWNLOADABLE RESOURCES

Technical documents

Open manufacturer PDFs directly from our website and save them to your device. Check the model and document revision.

Frequently asked questions

Which connection details are needed?+

Specify the thread size and standard; a coupling dimension alone is not sufficient.

Can both published maxima be used together?+

63 bar and 180 °C are separate catalogue maxima. Check the pressure–temperature relationship for the selected size and materials before applying them together.

What should I verify before specifying Truevalve Electrically Actuated Threaded Ball Valve?+

Evaluate pressure and temperature together. Verify the ratings that apply to the selected body, sealing materials and end connections in the model-specific technical document.

What should I include in my quotation request?+

Line size and connection standard; Fluid, operating pressure and temperature; Isolation or control duty and actuation method. For replacement equipment, also provide the nameplate and connection dimensions.

Where can I check the technical drawing and dimensions?+

Open the manufacturer PDF in the Technical Documents section. Match the relevant entry to the product type, nominal size and variant code. Not every option in a family catalogue belongs to the same product.