Experience that keeps you flowing.
Bursa, Türkiyeinfo@parlaproses.com

SX 2-3

SX 2 and SX 3 drainage pumps for compact sumps

Flygt SX 2-3 drains water from basements, garages and rainwater tanks. At 50 Hz the SX 2 and SX 3 have distinct curves. Add discharge-line losses to the lift from the sump and compare the resulting duty; a model’s maximum flow and maximum head are not delivered simultaneously.

SX 2 is single-phase; SX 3 supply and float options depend on the version.Stainless steel outer casing; pumped water cools the motor.
SX 2 limits (50 Hz)135 L/min; 7 m (separate limits)
SX 3 limits (50 Hz)225 L/min; 11 m (separate limits)
Technical documents

Final performance and suitability are verified for the selected model and duty point.

UNDERSTAND THE APPLICATION

A solution for your application.

Application areas

Emergency drainage of basements and garages · Water transfer or garden irrigation from rainwater tanks

Selection considerations

Establish solids size, fibrous content, sump geometry and minimum liquid level. Drainage and sewage pumps have different application limits.

Share your operating conditions with our technical team. We can assess liquid compatibility, hydraulic duty point and installation requirements together to identify the suitable variant.

MANUFACTURER DATA

Technical specifications

SX 2 limits (50 Hz)135 L/min; 7 m (separate limits)
SX 3 limits (50 Hz)225 L/min; 11 m (separate limits)
Maximum immersion5 m
Maximum liquid temperature40 °C

Values describe the published product family. Maximum flow and maximum head do not represent the same duty point. Verify selection against the specific model curve and current technical data.

DOWNLOADABLE RESOURCES

Technical documents

Open manufacturer PDFs directly from our website and save them to your device. Check the model and document revision.

Frequently asked questions

Will the SX 2 deliver 135 L/min at 7 m?+

No. These are different limits of the curve. Read flow at your actual total head on the SX 2 curve.

What should I check when selecting a float for a narrow sump?+

Supply the internal sump dimensions and intended switching levels. Leave room for the float to move without catching on the wall or pipe.

Which applications is Flygt SX 2-3 used for?+

Flygt SX 2-3 drains water from basements, garages and rainwater tanks. At 50 Hz the SX 2 and SX 3 have distinct curves. Add discharge-line losses to the lift from the sump and compare the resulting duty; a model’s maximum flow and maximum head are not delivered simultaneously. Example applications: Emergency drainage of basements and garages; Water transfer or garden irrigation from rainwater tanks.

What is the sx 2 limits (50 hz) specification for Flygt SX 2-3?+

SX 2 limits (50 Hz): 135 L/min; 7 m (separate limits). Verify against the complete model code, frequency and operating conditions.

What is the sx 3 limits (50 hz) specification for Flygt SX 2-3?+

SX 3 limits (50 Hz): 225 L/min; 11 m (separate limits). Verify against the complete model code, frequency and operating conditions.

What is the maximum immersion specification for Flygt SX 2-3?+

Maximum immersion: 5 m. Verify against the complete model code, frequency and operating conditions.

Which design features influence selection of Flygt SX 2-3?+

SX 2 is single-phase; SX 3 supply and float options depend on the version. Stainless steel outer casing; pumped water cools the motor. Assess these features with flow, head, fluid and installation conditions.

Which selection conditions should I check for Flygt SX 2-3?+

Establish solids size, fibrous content, sump geometry and minimum liquid level. Drainage and sewage pumps have different application limits.

Can Flygt SX 2-3 run dry?+

Dry running and dry installation are different. Even variants approved for dry installation require the specified liquid flow and motor cooling. Verify minimum level, permitted installation and thermal protection in the exact model manual.

How can I access PDF documents for Flygt SX 2-3?+

The Technical Documents section lists 1 document links. PDFs open on the Parla site. Check model, language, 50/60 Hz and revision; document types may vary by product.

What should I include in a quotation request for Flygt SX 2-3?+

Share minimum, normal and maximum flow, total head, liquid and temperature, power supply, suction and installation conditions. For replacements add the nameplate, connection dimensions and measured operating values.

Chat on WhatsApp